Post Offer Free
UNIVERSAL CABLES LIMITED  

Gold Index: 9714

You are here: home  > 600/1000V SR Insulated Flexibles Fire Resistant Control Cables (2-4 Cores & Multicores)

600/1000V SR Insulated Flexibles Fire Resistant Control Cables (2-4 Cores & Multicores) 

Place of Origin: , China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail


600/1000V SR Insulated Flexibles Fire Resistant Control Cables (2-4 Cores & Multicores),Fire Resistant Power And Control Cables

600/1000V SR Insulated Flexibles fire resistant Control Cables (2-4 Cores & Multicores)(CU/SR/LSZH 600/1000V Class 2)(CU/SR/LSZH 600/1000V Class 5)Application:The cables are designed for power supply and signals trasmission,Website:http://www.ue-cable.com, indoor or outdoor even wet environment. They are designed for fixed laying in free air, in pipe or conduit, on masonry and metal structures or suspended in places where in case of fire people are exposed to serious risks for emission of smoke, toxic and corrosive gases and where you want to avoid damage to facilities, equipment, goods. They are primarily intended for feeding of: emergency exits, alarm signals, warning of smoke or gas, escalators.STANDARDS:Basic design adapted from BS 7629-1FIRE PERFORMANCECircuit IntegrityIEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);BS 8434-1 (30mins); BS 5839-1 Clause 26 2d; CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)Circuit Integrity with mechanical shockEN 50200(PH60); CEI 20-36/4-0Circuit Integrity with mechanical shock & water sprayEN 50200 annex ESystem circuit integrityDIN 4102-12, E30 depending on lay systemFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.VOLTAGE RATING600/1000 VCABLE CONSTRUCTION Conductors:Plain annealed copper wire, stranded for section up to 10mm2 according to IEC(EN)60228 class 2 or flexible for section above 10mm2 according to IEC(EN) 60228 class 5.Insulation: Fire resistant silicone rubber compound type EI2 as per BS 7655-1.1.Cabling: The cores are cabled together in concentric layers with suitable non-hygroscopic fillers.Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZHcompound type SW2-SW4 as per BS 7655-2.6 can be offered.)COLOUR CODEInsulation Colour:Without earth conductor2 cores blue - brown3 cores brown - black - grey4 cores blue - brown - black - grey5 cores blue - brown - black - grey - black With earth conductor3 cores yellow/green - blue - brown4 cores yellow/green - brown - black - grey5 cores yellow/green - blue - brown - black - greySheath Colour: red (other colours on request).Physical AND THERMAL PROPERTIESTemperature range during operation (fixed state): -30°C – +90°CTemperature range during installation (mobile state): -20°C – +50°CMinimum bending radius: 6 x Overall DiameterElectrical PROPERTIESDielectric test:3500 V r.m.s. x 5' (core/core)Insulation resistance≥300 MΩ x km (at 20°C)Short circuit temperature350°CCONSTRUCTION PARAMETERSCable CodeNo. of Core X Cross SectionNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox.Weightmm2mmmmmmkg/km2 core600/1000V(PH60)2x1.51.01.29,2124600/1000V(PH60)2x2.51.11.310,0155600/1000V(PH60)2x4.01.11.411,2207600/1000V(PH60)2x6.01.11.513,1298600/1000V(PH60)2x101.11.615,9441600/1000V(PH60)2x161.11.717,46023 core600/1000V(PH60)3x1.51.01.29,8148600/1000V(PH60)3x2.51.11.310,6188600/1000V(PH60)3x4.01.11.412,1263600/1000V(PH60)3x6.01.11.514,4372600/1000V(PH60)3x101.11.616,8541600/1000V(PH60)3x161.11.719,47774 core600/1000V(PH60)4x1.51.01.310,6176600/1000V(PH60)4x2.51.11.411,5228600/1000V(PH60)4x4.01.11.513,6332600/1000V(PH60)4x6.01.11.611,5214600/1000V(PH60)4x101.11.718,5680600/1000V(PH60)4x161.11.821,29735 core600/1000V(PH60)5x2.51.11.412,6266600/1000V(PH60)5x4.01.11.514,5399600/1000V(PH60)5x6.01.11.617,6576600/1000V(PH60)5x101.11.720,5850600/1000V(PH60)5x161.11.823,31202Electrical PROPERTIESConductor Operating Temperature : 90°CAmbient Temperature : 30°CCurrent-Carrying Capacities (Amp)NominalCrossSectionAreaReferenceMethod 4(enclosed in an conduitinsulated wall etc)Reference Method 3(enclosed in conduit on a wall or ceiling, or in trunking)Reference Method 1 (clipped direct)Reference Method 11(on a perforated cable tray), or Reference Methodone 3-corecable or one4-core cable3-phase a.c.one 2-core cable single phasea.c. or d.c.one 3-corecable or one 4-core cable 3-phase a.c.one 2-corecable singlephasea.c. or d.c.one 3-core cable or one 4-core cable3-phase a.c.one 2-corecable singlephasea.c. ord.c.one 3-core cable or one4-core cable3-phase a.c.12345678mm2AAAAAAA1.516.52219.5242226232.52230263330363243040354540494263851445852635410516960807186751668918010796115100Voltage Drop (Per Amp Per Meter)Nominal Cross Section Area2-core cable d.c.2-core cable single- phase a.c3-core or 4-core cable 3-phase a.c.1234mm2mV/A/mmV/A/mmV/A/m1.53131272.5191916412121067.97.96.8104.74.74162.92.92.5
bigPhoto
 Ms. HelenWong

Tel: 86-531-88817113
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

UNIVERSAL CABLES LIMITED [China (Mainland)]


Business Type:Manufacturer
City: Jinan
Province/State: Shandong
Country/Region: China (Mainland)

You May Like:

Product (274)