Flame Retardant RS485 Databus Cables PVC Sheath
Place of Origin: |
, China (Mainland) |
Product Detail
Flame Retardant RS485 Databus Cables PVC Sheath,Flame Retardant Data Cables PVC Sheath
Flame Retardant RS485 Databus Cablespplication:The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed,Website:http://www.ue-cable.com, interference free, data transmission where continued functionality is required during a fire situation.STANDARDS:Basic design adapted to EIA/TIA 485FIRE PERFORMANCEFlame Retardance (Single Vertical Wire Test)**EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)**EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.CABLE CONSTRUCTIONMultipair RS 485 Overall Screened Databus CableConductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Foam PE or foam skin PE.Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.Cabling: Pairs are cabled together in concentric layers.Overall screen: Aluminum/polyester tape with tinned copper drain wire.Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.Multipair RS 485 Overall Double Screened Databus CableConductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Foam PE or foam skin PE.Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.Cabling: Pairs are cabled together in concentric layers.Overall screen: Aluminium/polyester tape+copper wire braid.Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.Multipair RS 485 Individual & Overall screened Databus CableConductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Foam PE or foam skin PE.Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.Cabling: Pairs are cabled together in concentric layers.Individual Screen: Individual aluminium/polyester tape.Overall Screen: Copper wire braid.Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.Multipair RS 485 Overall Screened Databus CableConductors: tinned copper wire, stranded according to IEC(EN) 60228 class 2.Insulation: Foam PE or foam skin PE.Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation.Cabling: Pairs are cabled together in concentric layers.Overall Screen: Copper wire braid.Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.Physical AND THERMAL PROPERTIESTemperature range during operation (fixed state): -20°C - +90°CTemperature range during installation (mobile state): -5°C - +60°CMinimum bending radius: 8 x Overall DiameterElectrical PropertiesDielectric test1000 V r.m.s. for 5' (core-core)1000 V r.m.s. for 5' (core-screen)Impedance120Ωcapacitance45 nF/km conductor to conductor90 nF/km conductor to shieldCONSTRUCTION PARAMETERSMultipair RS 485 Overall Screened Databus CableRE-02Y(St)Y / RE-02YS(St)YNo.of pair xNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox. Weightmm2No/mmmmmmmmkg/km10.227/0.20.550.404.02120.227/0.20.550.407.14240.227/0.20.550.408.36810.5016/0.20.550.404.63220.5016/0.20.550.408.26840.5016/0.20.550.409.811510.7524/0.20.550.405.14020.7524/0.20.550.409.18440.7524/0.20.550.4010.914411.0030/0.20.550.405.24921.0030/0.20.550.409.510541.0030/0.20.550.4011.2182Multipair RS 485 Overall Double Screened Databus CableRE-02Y(St)CY / RE-02YS(St)CYNo.of pair xNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox. Weightmm2No/mmmmmmmmkg/km10.227/0.20.550.404.53420.227/0.20.550.407.56740.227/0.20.550.408.89710.5016/0.20.550.405.14820.5016/0.20.550.408.79740.5016/0.20.550.4010.315010.7524/0.20.550.405.65720.7524/0.20.550.409.711640.7524/0.20.550.4011.418211.0030/0.20.550.405.76721.0030/0.20.550.4010.013841.0030/0.20.550.4011.8222Multipair RS 485 Individual & Overall screened Databus CableRE-02Y(St)Y pimf / RE-02YS(St)Y pimfNo.of pair xNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox. Weightmm2No/mmmmmmmmkg/km10.227/0.20.550.404.43520.227/0.20.550.407.56940.227/0.20.550.408.810610.5016/0.20.550.405.04920.5016/0.20.550.408.710040.5016/0.20.550.4010.315910.7524/0.20.550.405.55820.7524/0.20.550.409.711940.7524/0.20.550.4011.217411.0030/0.20.550.405.66821.0030/0.20.550.4010.014241.0030/0.20.550.4011.8234Multipair RS 485 Overall Screened Databus CableRE-02YCY / RE-02YSCYNo.of pair xNominal Cross Sectional AreaNo./Nominal Diameter of StrandsNominal Insulation ThicknessNominal Sheath ThicknessNominal Overall DiameterApprox. Weightmm2No/mmmmmmmmkg/km10.227/0.20.550.404.33120.227/0.20.550.407.36140.227/0.20.550.408.59110.5016/0.20.550.404.94420.5016/0.20.550.408.59140.5016/0.20.550.4010.014210.7524/0.20.550.405.45320.7524/0.20.550.409.510940.7524/0.20.550.4011.217411.0030/0.20.550.405.56321.0030/0.20.550.409.813141.0030/0.20.550.4011.5213
Related Search
Find more related products in following catalogs on Hisupplier.com