Post Offer Free
UNIVERSAL CABLES LIMITED  

Gold Index: 9714

You are here: home  > Fire Resistant UTP CAT5 Data Cables

Fire Resistant UTP CAT5 Data Cables 

Place of Origin: , China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail


Fire Resistant UTP CAT5 Data Cables,Fire Resistant Signal And Data Cables

Fire Resistant UTP CAT5 Data Cables FR-CAT5UTP4P24Application:The cables are desgined for structure wiring,Website:http://www.ue-cable.com, compatible with all known connection systems according to EN 50173. Based on the design for structured wiring (found in IEC 61156 and BS EN 50288), this cable brings together high frequency data transmission and circuit integrity in four pair cable that will continue to transmit data even when being directly attacked by fire.STANDARDS:Basic design to EN 50173VOLTAGE RATING:60VFIRE PERFORMANCECircuit IntegrityIEC 60331-23; BS 6387 CWZ; DIN VDE 0472-814(FE180);CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)System circuit integrityDIN 4102-12, E30 depending on lay systemFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Note: Asterisk * denotes superseded standard.CABLE CONSTRUCTIONConductors: Plain annealed copper wire, solid according to IEC(EN) 60228 class 1.Insulation: PE wrapped with fire resistant silicone rubber compound type EI2 as per BS 7655-1.1.Twisted Pairs: Insulated conductors are twisted into pairs with varying lay length to minimizecrosstalk.Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimizecrosstalk. Two-pair cable had four cores laid in quad formation.Cabling: Pairs are cabled together in concentric layers.Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZHcompound type SW2-SW4 as per BS 7655-2.6 can be offered.)Physical AND THERMAL PROPERTIESTemperature range during operation (fixed state): -5℃ - +50℃Temperature range during installation (mobile state): -20℃ - +90℃Minimum bending radius: 8 x Overall DiameterElectrical PropertiesCharacteristic Impedance100 Ohm±15%Nominal Velocity of Propagation (NVP)69%Max. Dc Resistance9.38 Ohm/100mMax. Resistance Unbalance5%Max. Mutual Capacitance:5.6 nF/100mMaximum Capacitance Unbalance330 pF/100mMax. Propagation Delay Skew30 ns/100mMax. Propagation Delay536 ns/100m@100 mhzMax. Pulling Load80NTransmission PropertiesFREQ (MHz)NEXT(dB/100m)Minimum Value/Typical Value/ Standard ValueIL (dB/100m)SRL (dB/100m)Minimum Value/Typical Value/ Standard Value164.0/71.0/62.02.024.5/26.0/23.0455.0/62.0/53.04.024.5/26.0/23.0849.5/57.0/48.05.724.5/26.0/23.01049.0/56.0/47.06.424.5/26.0/23.01644.9/52.0/44.08.224.5/26.0/23.02042.5/48.0/42.09.224.5/26.0/23.02542.0/48.0/41.010.324.5/26.0/23.031.2540.6/48.0/39.011.622.5/24.0/21.062.536.1/43.0/35.016.919.5/22.0/18.010034.0/40.0/32.021.817.5/20.0/16.0CONSTRUCTION PARAMETERSCable CodeConductorDiameterNominal Insulation ThicknessNominal Overall DiametermmmmmmFR-CAT5UTP4P240.50.255.3
bigPhoto
 Ms. HelenWong

Tel: 86-531-88817113
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

UNIVERSAL CABLES LIMITED [China (Mainland)]


Business Type:Manufacturer
City: Jinan
Province/State: Shandong
Country/Region: China (Mainland)

You May Like:

Product (274)